Efficiency and sustainability

Passive house: what it is, what it requires and when it makes sense

A passive house is a building designed to need very little energy for heating and cooling, while remaining comfortable throughout the year. It achieves this through construction, not equipment: continuous insulation, no thermal bridges, airtightness, high-performance openings and ventilation with heat recovery. The name comes from the Passivhaus standard, of the Passivhaus Institut, in Germany.

By Sofia Silva30 April 202312 min read

Passive house: what it is, what it requires and when it makes sense

Photography: Unsplash.

In short

  • A passive house reduces heating and cooling needs to a minimum through design and construction, not equipment.
  • It rests on five principles: continuous insulation, elimination of thermal bridges, airtightness, ventilation with heat recovery and high-performance openings.
  • It requires rigorous design, specialised labour and checks on site, including an airtightness test.
  • To be Passivhaus certified, the building has to be calculated with PHPP and meet the standard; an efficient or nZEB building is not, in itself, a passive house.
  • Passivhaus certification is separate from the mandatory energy certificate (SCE).
  • In existing buildings, the standard is harder to achieve; for rehabilitation there is the EnerPHit standard.

What is a passive house?

The passive house, or Passivhaus, is a way of building that maximises energy efficiency and the comfort of its occupants, according to a performance standard developed by the Passivhaus Institut.

The idea is simple: instead of compensating for heat losses with equipment, the losses are avoided. The aim is comfort without energy-intensive heating and cooling systems.

Portuguese law does not require the passive house. What it requires is that new buildings be nearly zero energy buildings, nZEB (Decree-Law No. 101-D/2020, as currently in force). The Passivhaus standard is the building owner's choice and is more demanding on several points, such as airtightness. On the legal threshold, see nZEB buildings.

What principles define a passive house?

Continuous thermal insulation

Insulation is the central element. It should wrap the house without interruptions, ideally from the outside, as with the ETICS system, to limit heat losses in winter and heat gains in summer. The appropriate thickness depends on the climate, the form and the orientation of the building, and is defined in the calculation.

Insulating external walls from the inside, common in renovations, is interrupted at slabs and interior walls and makes it very difficult to reach the standard. See what this solution allows in internal wall insulation.

Elimination of thermal bridges

Thermal bridges are weak points in the envelope, through which heat is lost. They also encourage condensation, damp and mould. They have to be resolved right from the design stage, in areas such as roller shutter boxes, beams, columns, balconies, openings and junctions between elements. On site, they can be detected with thermography.

Airtightness

Uncontrolled air leaks cause energy losses, condensation inside the walls and poorer air quality. Airtightness is achieved with a continuous sealing layer, designed in the project, and with care over the trims, joints and sealing tapes around windows, doors and pipe penetrations. It is checked with a pressurisation test (blower door).

Mechanical ventilation with heat recovery

In an airtight house, the air is renewed by a mechanical system that uses the heat from the extracted air to preheat the fresh air in winter, without the two flows mixing. It ensures good indoor air quality and helps to control humidity. The windows can still be opened; they are simply no longer needed to renew the air.

High-performance openings

Windows and doors are a major source of losses and gains. To a passive standard, frames with an effective thermal break and low-emissivity glazing are used. In cold climates, triple glazing is the rule; in mild climates, such as much of Portugal, the glazing make-up is decided in the calculation. Correct installation is as important as the product. See aluminium or PVC windows.

How is a passive house designed?

The design counts from the very first decision: compact form, orientation, the position and size of openings, insulation and ventilation.

Whenever possible, living spaces are oriented to the south, to capture solar energy, with adequate shading in summer, and bathrooms, storage, circulation and garage are placed to the north. This is not always possible: each plot and each brief has its constraints, and the design should explore the various options.

As the insulation is thicker, so are the walls, which counts in the siting and the areas. To see how these decisions follow on from one another, see the stages of an architectural project and bioclimatic architecture.

How much does it cost to build a passive house, and is it worth it?

Higher-performance materials, mechanical ventilation and specialised labour generally increase the initial investment compared with a conventional house.

In return, the lower energy need reduces the running cost over the life of the building. The comparison should be made as a whole: initial investment, running cost, maintenance and comfort. For reference values for works, use the renovation cost simulator; for your case, request a proposal.

What are its advantages and limits?

Advantages

  • Lower energy need for heating and cooling and, therefore, a lower carbon footprint in use.
  • Greater comfort: stable temperature, without cold walls or draughts.
  • Better indoor air quality, with filtered ventilation.

Limits

  • Higher initial investment.
  • Less design freedom: the form, the openings and some materials are constrained by the requirements.
  • Regular maintenance of the ventilation, including filter changes, to maintain performance.
  • It requires specialisation: not all building contractors are used to the rigour required on site.

How is a passive house certified?

Passivhaus certification follows the requirements of the Passivhaus Institut and is separate from the energy certificate of the Energy Certification System for Buildings (Sistema de Certificação Energética dos Edifícios, SCE), which is a legal requirement. It is carried out by a certifier accredited by the Passivhaus Institut, and the building only receives the certificate if it meets all the criteria.

The main criteria for a passive house are:

  • heating energy demand below 15 kWh per m² of useful floor area per year, or a heating load of up to 10 W/m²;
  • an equivalent limit for cooling;
  • airtightness of no more than 0.6 air changes per hour, measured in the pressurisation test at 50 Pa (n50);
  • excessive indoor temperatures for no more than 10% of the time.

There are three classes: Classic, Plus and Premium. Classic corresponds to the passive house without renewable energy generation. In Plus, renewable energy generation matches consumption on an annual average; in Premium, considerably more energy is produced than is consumed.

To be Passivhaus certified, the building has to be calculated with the Passive House Planning Package (PHPP) and meet all the requirements of the standard. A building can be highly efficient, and even nZEB, without being passive. If you buy a house presented as passive, ask for the certificate, confirm the certifying body and check whether the building is listed in the Passivhaus Institut's building database.

And in a rehabilitation, is it possible to reach the passive standard?

It is difficult. In an existing building, eliminating all thermal bridges and insulating from the outside is not always possible, especially on façades that are to be preserved. For these cases, the Passivhaus Institut has its own rehabilitation standard, EnerPHit.

The most realistic path is usually to improve thermal performance as far as the building's constraints allow. You can read more in nZEB buildings and sustainable house, and on the building rehabilitation page. For the broader framework, see urban rehabilitation and our rehabilitation service.

spacelovers is an architecture studio: it produces the design, handles the licensing and provides technical assistance during construction, coordinating the architecture with the energy performance project. Passivhaus certification is carried out by an independent certifier.

Frequently asked questions

Is an nZEB house a passive house?

Not necessarily. nZEB is the legal threshold for new buildings in Portugal. A building can be nZEB without meeting the Passivhaus standard; to be certified as passive, it has to be calculated with PHPP and meet all the requirements.

Can I insulate from the inside and have a passive house?

Hardly. Internal insulation is interrupted at slabs and interior walls and leaves thermal bridges that are difficult to resolve. It improves comfort, but as a rule does not reach the standard. In rehabilitation, the reference is the EnerPHit standard.

Does the Passivhaus certificate replace the energy certificate?

No. The SCE energy certificate is required by law in the cases it provides for. Passivhaus certification is not required by law and attests compliance with a private standard.

How can I confirm that a house really is passive?

Ask for the Passive House certificate, confirm the certifying body and check whether the building is listed in the Passivhaus Institut's building database.

This content is for information only and does not constitute legal advice. For your specific situation, legal advice should be provided by a qualified professional in the field.

Sofia SilvaFounder of spacelovers, an architecture and renovation studio in Lisbon.